top of page
Retrotec 5300 - Triple Fan Blower Door System

Retrotec 5300 - Triple Fan Blower Door System

This System has three Model 5000 Calibrated Fans in one Large Cloth panel door frame system. This is the most economical way to blow large quantities of air to test Commercial, Multi-Family or High Rise buildings.

The 3 included DM32 digital gauges are more advanced than any competitive gauge and ideal when running the 5311 manually or fully automatically using a computer and the optional Multi-FanTestic Software. The DM32 also allows tests when fans are separated by large distances. An available upgrade is the DM32 WiFi, which adds the wireless feature that generally is not needed for large set ups since wired connections are more dependable but works very well when distances are line of sight.

You may also run automatic data logging from multiple fans, and remote gauge control from a laptop. With our new 5 year recommended calibration interval on the DM32, you will have the peace of mind knowing that yearly calibrations are a thing of the past.

Calibrated range configurations allow one fan to test a wide range of enclosures, from super leaky to super tight. This high output fan includes 6 flow ranges to provide accurate results over the widest range of enclosure volumes. All Retrotec fans are made with extremely durable space-age plastic foam, which makes them both lightweight and tough. They are also easily reversible: to switch from pressurizing to depressurizing your enclosure, simply flip the fan around in its panel.

Run only a single Ethernet cable from test area to the laptop to control your test.

5000/6000 series blower doors DO NOT work with the DM-2 digital gauge

* The max flow of the fan will vary depending on the following factors:

voltage, frequency, barometric pressure, back pressure, blade pitch, air temperature, bearing tightness, inlet air turbulence

  • Technical Specifications:

    Model 5000 Fan
      Flow Into: CFM Litres/sec M3/h
    Max Flow, per fan (60 Hz) Free Air 6,400 3,020 10,874
      50 Pa 5,700 2,690 9,684
    Reduces values by 15% for 50Hz fan 75 Pa 5,400 2,549 9,175
    Minimum Flow:        
    on Included Range B1 50 Pa 111 52 188
    on Optional Range 74 50 Pa 37 17 63
    on Optional Range 47 50 Pa 21 10 35
    on Optional Range 29 50 Pa 9 4 15
    Dimensions: 22" (55.9 cm) inlet diameter, 9.75" (24.8 cm) long, 25" (63.5 cm) height
    Weight: 33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed
    Flow Accuracy: +/-5%
    Power: 120V@60hz/11A or 240V@50hz/4.9A or 110V@50Hz/ 8.9A
    Recommended Fan Calibration Interval: 5 years
    Digital Gauge Model: DM32 WiFi
       
    Door Panel and Frame Model: AL266
    Type of Panel:   Cloth For Large Frame – Triple 1000/3000/5000/6000 Fan
       
    Door Panel and Frame Model: AL261
    Type of Panel:   Cloth For Large Frame – Single 1000/3000/5000/6000 Fan
       
    Door Panel and Frame Model: AL260
    Type of Panel:   Large Frame – Single 1000/3000/5000/6000 Fan
    Type of Frame: Large Sized Red Anodized Frame 
    Collapsed: 31 5/8” X 59 1/2” (80.3cm X 151.1cm)
    Expanded: 51” X 109 1/4” (129.5cm X 277.5cm)
    Frame Thickness: 1.75” (5.3 cm)

    * The max flow of the fan will vary depending on the following factors:

    voltage, frequency, barometric pressure, back pressure, blade pitch, air temperature, bearing tightness, inlet air turbulence

     

bottom of page